{"title":"ECU ELECTRONICS","description":"","products":[{"product_id":"gsu-v2-ground-support-unit-for-jetcat-ecu-controllers","title":"GSU V2 (Ground Support Unit) , For JetCat ECU Controllers","description":"\u003ch2\u003eGSU V2 (Ground Support Unit) , For JetCat ECU Controllers\u003c\/h2\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0668\/4128\/0701\/files\/GSU-V2-Manual.pdf?v=1778252012\" target=\"_blank\" rel=\"noopener\"\u003eDownload the GSU V2 Manual Here\u003c\/a\u003e\u003c\/h3\u003e","brand":"JetCat","offers":[{"title":"Default Title","offer_id":46722676097213,"sku":"JC-61101-0010","price":189.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/4128\/0701\/files\/JC-61101-0010-gsu-ground-support-unit-jetcat-ecu-controller.jpg?v=1777484684"},{"product_id":"v-6-jetcat-replacement-ecu-for-all-engines-except-p20-se-rx-rxi-pro","title":"V-6 Jetcat Replacement ECU, For all Engines except P20-SE, RX, RXi, PRO","description":"\u003ch2\u003eV-6 Jetcat Replacement ECU, For all Engines except P20-SE, RX, RXi, PRO\u003c\/h2\u003e","brand":"JetCat","offers":[{"title":"Default Title","offer_id":46722676162749,"sku":"JC-61102-0000","price":369.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/4128\/0701\/files\/JC-61102-0000-v6-jetcat-ecu-turbiine-engine.jpg?v=1777484688"},{"product_id":"v-12-jetcat-replacement-ecu","title":"V-12 Jetcat Replacement ECU","description":"\u003ch2\u003eV-12 Jetcat Replacement ECU\u003c\/h2\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0668\/4128\/0701\/files\/ecu-bat.pdf?v=1778252010\" target=\"_blank\" rel=\"noopener\"\u003eDownload the ECU Battery Compatibility Chart Here\u003c\/a\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePowerful 16\/32 bit microcontroller of the latest generation, with generously dimensioned program and data memory Integrated failsafe counter with evaluation and display of the number and duration of errors. This can be assessed after landing the quality of the radio link.\u003c\/li\u003e\n\u003cli\u003eThanks to the integrated flash program memory, software updates can simply be imported from outside via the serial interface.\u003c\/li\u003e\n\u003cli\u003eProgrammable failsafe behavior. The Hold and Failsafe times as well as the FailSafe speed can be programmed.\u003c\/li\u003e\n\u003cli\u003eUSB \/ RS232 interface for computer connection (allows complete control of one or more turbines via a computer)\u003c\/li\u003e\n\u003cli\u003eSwitchable start mode: propane start or jet start\u003c\/li\u003e\n\u003cli\u003eTurbine control optionally via one or two channels\u003c\/li\u003e\n\u003cli\u003eDirect start and control of the turbine from the GSU, even without the remote control transmitter.\u003c\/li\u003e\n\u003cli\u003eFunctions to easily start multiple turbines in parallel on the receiver side (for example, multi-engine models)\u003c\/li\u003e\n\u003cli\u003eActivatable gas release function after successful start of the turbine (there will be no gas on board in flight).\u003c\/li\u003e\n\u003cli\u003eActivatable warning functions via the smoker valve, generates warning signals in case of battery under voltage, empty tank, or FailSafe.\u003c\/li\u003e\n\u003cli\u003eIntegrated data logger function. The data of the last 14 minutes of operation (800 data records) are stored with a resolution of one second, and can be read out by means of the PC software. The data remains stored even after power failure. In addition, the last 8 operating seconds before shutting down the turbine are stored with a resolution of 0.2 seconds. This allows for precise fault diagnosis.\u003c\/li\u003e\n\u003cli\u003eAirspeed sensor input for measurement \/ control \/ model airspeed limitation.\u003c\/li\u003e\n\u003cli\u003eIntelligent \"Run\" menu: The displayed information is switched depending on the operating status\u003c\/li\u003e\n\u003cli\u003eAdvanced test and diagnostic functions for pump, valves and sensors.\u003c\/li\u003e\n\u003cli\u003eAuto power down function, the ECU switches off automatically after cooling down (RC system can be switched off, ECU remains ON until the cooling process has ended).\u003c\/li\u003e\n\u003cli\u003eTolerant fault detection of the connected sensors. Thus, in the case of a defective sensor, the turbine is not shut down rigorously, but an emergency mode is activated, which normally enables the safe termination of the flight. After landing, a restart is only possible after troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eAdditional features ECU V12.0:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBarometric pressure and height sensor\u003c\/li\u003e\n\u003cli\u003eIntegrated telemetry converter for:\n\u003cul\u003e\n\u003cli\u003eGraupner HOTT\u003c\/li\u003e\n\u003cli\u003eFutaba S-BUS2\u003c\/li\u003e\n\u003cli\u003eMultiplex MSB\u003c\/li\u003e\n\u003cli\u003eJeti\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUSB interface for:\n\u003cul\u003e\n\u003cli\u003eOnline Software Updates\u003c\/li\u003e\n\u003cli\u003eReadout of the integrated data logger\u003c\/li\u003e\n\u003cli\u003eRemote control of the turbine and display of turbine parameters via computer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eInput voltage: 7-15V\u003c\/li\u003e\n\u003cli\u003eDimensions: (L: 54 mm, W: 34 mm, H: 11 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"5\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eECU V5\/6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eECU V10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eECU V12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePro Turbine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eP20 ECU V10 \/ V12\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2s Lipo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3s Lipo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLi-Ion 3s\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3s Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003ePossible, Not Recommended\u003c\/td\u003e\n\u003ctd\u003ePossible, Not Recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4s Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e6S\u003c\/strong\u003e \u003cstrong\u003eNiCd\/NiMh\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e6-11s\u003c\/strong\u003e \u003cstrong\u003eNiCd\/MiMh\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePb 4-6S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"JetCat","offers":[{"title":"Default Title","offer_id":46722676195517,"sku":"JC-61102-0025","price":369.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/4128\/0701\/files\/JC-61102-0025-v12-jetcat-ecu-enge-control-unit-turbine-engine.jpg?v=1777484687"},{"product_id":"jetcat-battery-management-system-bms-for-powerbox-batteries","title":"JetCat Battery Management System (BMS), for PowerBox Batteries","description":"\u003ch2\u003eJetCat Battery Management System (BMS), for PowerBox Batteries\u003c\/h2\u003e\r\n\u003cp\u003eThe JetCat BMS (Battery Management System) system solves several necessities when charging the engine and receiver batteries from an engine powered generator system:. 1) Precise measurement of the cell voltages of the engine battery, and forwarding of this information to the ECU and generator charging system. 2) Balancing of the engine battery cells. 3) Output control and current measurement of the two charging outputs to the receiver batteries. 4) Reporting of all charge currents \/ voltages and charged capacities to the ECU. Receiver batteries must contain an onboard charging\/balancing system, i.e. batteries from PowerBox Systems, other batteries may be adapted for use. BMS cables supplied designed for Powerbox LiPo and LiFe chemistry batteries.\u003c\/p\u003e","brand":"JetCat","offers":[{"title":"Default Title","offer_id":46722676981949,"sku":"JC-61108-0060","price":119.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/4128\/0701\/files\/JC-61108-0060-jetcat-battery-management-system-bms-powerbox-batteries.jpg?v=1777484688"},{"product_id":"telemetry-adapter-for-jetcat-v10-v6-ecu-models","title":"Telemetry Adapter, for JetCat V10\/V6 ECU Models","description":"\u003ch2\u003eTelemetry Adapter, for JetCat V10\/V6 ECU Models\u003c\/h2\u003e \u003cul\u003e\n\u003cli\u003eThe JetCat telemetry adapter connects directly to the ECU data bus. \u003c\/li\u003e\n\u003cli\u003eThe output of the telemetry adapter is typically directly connected to the receiver (Telemetry input of the receiver). \u003c\/li\u003e\n\u003cli\u003eThe adapter has two outputs connected in parallel so that another device or sensor can be connected to the 2nd port. \u003c\/li\u003e\n\u003cli\u003eThe following values can be transferred depending on the system used:\u003c\/li\u003e\n\u003c\/ul\u003e \u003cul\u003e \u003cli\u003eExhaust gas temperature in ° C\u003c\/li\u003e \u003cli\u003eTurbines actual speed in 1\/min\u003c\/li\u003e \u003cli\u003ePump voltage in V\u003c\/li\u003e \u003cli\u003eVoltage of the turbine battery in V\u003c\/li\u003e \u003cli\u003eCurrent consumption in A. Only for ECU V10.0 or higher\u003c\/li\u003e \u003cli\u003eBattery capacity in mAh (Turbine battery). Only for turbines with generator function (for example P220RXi, P180-NX)\u003c\/li\u003e \u003cli\u003eTurbine state and error codes\u003c\/li\u003e \u003cli\u003erest fuel in ml \/ rest fuel in%\u003c\/li\u003e \u003cli\u003efuel flow in ml\/min\u003c\/li\u003e \u003cli\u003eAltitude in meters. Only with ECU V10.0 or higher\u003c\/li\u003e \u003cli\u003eThrust in N\u003c\/li\u003e \u003cli\u003eTurbines Set speed in 1\/min\u003c\/li\u003e \u003cli\u003eAirspeed in km\/h\u003c\/li\u003e \u003cli\u003eSpeed of second shaft (propeller speed for turboprops or main rotor speed for helicopter engines)\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eStarting Telemetrie Adapter with firmware V. 9.0, the following systems are supported:\u003c\/p\u003e \u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e \u003c\/th\u003e \u003cth\u003e    V10.0    \u003c\/th\u003e \u003cth\u003e    V6.0    \u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAb ECU Software Version           \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e10.4P\u003c\/td\u003e \u003ctd\u003e6.42\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFutaba SBUS-2\u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eGraupner HOTT\u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMPX M-Link1\u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMPX M-Link2\u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eJeti\u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eJeti-NoAlarms\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMikado Vbar\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003e✓\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePowerBox Core\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSpektrum\u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eATTENTION:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eECU V5\/6: LED I\/O board 61108-0000 with 8-pin ERNI socket necessary\u003c\/li\u003e \u003cli\u003eECU V10 LED I\/O board Mini 61108-0050 necessary\u003c\/li\u003e \u003cli\u003eECU V6 with firmware 6.42 or higher required\u003c\/li\u003e \u003c\/ul\u003e","brand":"JetCat","offers":[{"title":"Default Title","offer_id":46722677014717,"sku":"JC-61108-0070","price":119.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/4128\/0701\/files\/JC-61108-0070-telemetry-adapter-jetcat-v10-v6-ecu.jpg?v=1777484689"},{"product_id":"mini-gsu-ground-support-unit-for-jetcat-v12-ecu-controllers","title":"Mini GSU (Ground Support Unit) , For JetCat V12 ECU Controllers","description":"\u003ch2\u003eMini GSU (Ground Support Unit) , For JetCat V12 ECU Controllers\u003c\/h2\u003e\r\n\u003cp\u003eThe JetCat Mini-GSU is an optional miniaturized Ground Support Unit (GSU). The Mini-GSU is so small that it can easily remain in the model if desired. The 2-line, backlit, alphanumeric LCD display and the 10 function keys offer the same operations as the \"large\" GSU. The connection to V6 and lower ECUs is done via an 8-pin ribbon cable and connector directly to the LED-I\/O interface.\u003c\/p\u003e\r\n\u003cp\u003eThe connection to V10 \u0026amp; up ECUs is made either directly to the ECU or to the standard LED-I\/O interface via a 6-pin ribbon cable or via an 8-pin ribbon cable and connector to the JetCat I\/O interface with charging input.\u003c\/p\u003e\r\n\u003cul\u003e\n\u003cli\u003eDimensions (L\/W\/H): 66 mm x 34 mm x 19 mm\r\n\u003c\/li\u003e\n\u003cli\u003eWeight: 49.7 g\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"JetCat","offers":[{"title":"Default Title","offer_id":46722677473469,"sku":"JC-61161-0000","price":119.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/4128\/0701\/files\/JC-61161-0000-mini-gsu-ground-support-unit-jetcat-v12-ecu-controller.jpg?v=1777484695"},{"product_id":"pro-interface-v2-for-jetcat-turbine-engines","title":"PRO-Interface V2, for JetCat Turbine Engines","description":"\u003ch2\u003ePRO-Interface V2, for JetCat Turbine Engines\u003c\/h2\u003e\r\n\u003cp\u003eBy using the JetCat PRO interface V2 adapters, not only can all PRO turbines be quickly and easily deployed in model aircraft applications, but it also provides a complete solution and easy access point for stationary and industrial applications.  It also allows you to use the full functionality of our JetCat telemetry adapters.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eGeneral features:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\t\u003cli\u003e\u003cstrong\u003eOne or two channel RC control (From receiver)\u003c\/strong\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cstrong\u003eTelemetry output for: Jeti, Graupner Hott, Multiplex M-BUS and Futaba SBUS-2\u003c\/strong\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cstrong\u003eRJ12 socket for connecting the GSU\u003c\/strong\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cstrong\u003eAirspeed sensor 6 and 8-pin ERNI flat cable connectors (e.g. for LCU \/ Mini GSU connection)\u003c\/strong\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cstrong\u003eRS232 header for computer control\u003c\/strong\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cstrong\u003eCAN bus header\u003c\/strong\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cstrong\u003eHeader to JetCat BMS (Battery Management System)\u003c\/strong\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cstrong\u003eCross-check communication port (for connecting \/ synchronizing two turbines)\u003c\/strong\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cstrong\u003e3x Status LEDs\u003c\/strong\u003e\u003c\/li\u003e\r\n\t\u003cli\u003e\u003cstrong\u003eAnalog and digital inputs for:\u003c\/strong\u003e\u003c\/li\u003e\r\n\t\u003cli\u003eSwitch on \/ switch off\u003c\/li\u003e\r\n\t\u003cli\u003eTurbine On \/ Off Control\u003c\/li\u003e\r\n\t\u003cli\u003eTurbine RPM Command \/ control via a directly connected potentiometer\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"JetCat","offers":[{"title":"Default Title","offer_id":46722677670077,"sku":"JC-61168-0020","price":229.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/4128\/0701\/files\/JC-61168-0020-pro-interface-v2-etcat-turbine-engine.jpg?v=1777484697"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/4128\/0701\/collections\/JC-61102-0025-v12-jetcat-ecu-enge-control-unit-turbine-engine.jpg?v=1779723281","url":"https:\/\/www.chiefrc.com\/collections\/ecu-electronics.oembed","provider":"Chief RC Inc","version":"1.0","type":"link"}